UNDERGROUND STORAGE TANK REMOVAL:
QUANTITATIVE MEASUREMENT OF GASOLINE RANGE PETROLEUM HYDROCARBONS AND BENZENE, TOLUENE, ETHYLBENZENE AND XYLENE IN SOIL


(EPA Method 5030B/8015M; 5030B/8021B; Test Methods
For Evaluating Solid Waste SW 846)

[ISBN 0-9621181-5-X ]

$7.95 (US)

Format:

(15 Pages of Text + 13 Exhibits)

Pursuant to California Code of Regulations Section 2672 owners or operators of underground storage tanks used to store gasoline or other petroleum products at permitted sites must apply to the appropriate regulatory agency for permanent underground storage tank closure in the event that said storage tanks are to be permanently removed from the permitted site. The owner or operator of an underground storage tank being closed must demonstrate to the satisfaction of the local agency that no unauthorized release of hazardous substance has occurred. This demonstration must be based on soil sample analysis performed during or immediately after closure activities [Cal. Code Reg Section 2672(d)].

This treatise reports and summarizes the results of Quantitative Gas Chromatography Analysis of Four (4) soil samples collected during UST removal from specified locations in a dirt pit that had accomodated two (2) 12000 gallon double walled, fiberglass coated underground storage tanks. Reported herein are the Analytical Results including concentration estimates for Gasoline Range Organics (C4-C10) and Benzene, Toluene, Ethylbenzene, Xylene and Methyl Tert Butyl Ether, detected in these soil samples.

CONTENTS

I. Conclusions

II. Analysis For Total Petroleum Hydrocarbon
(C4-C10 Hydrocarbon) and Benzene, Toluene, Ethylbenzene and Xylene)
      A. Summary of Analytical Results
      B. Regulatory Backround

III. Analytical Methods
      A. EPA Method 8015M For Total Petroleum Hydrocarbon;
       EPA Method 8021B for Benzene, Toluene, Ethylbenzene,
      Xylene, MTBE; EPA Method 5030B Purge and
       Trap Sample Preparation

IV. Analytical Results
      A. Total Petroleum Hydrocarbon-External Standard Calibration
      B. Benzene, Toluene, Ethylbenzene, Xylene (BTEX)
      C. Quality Control Testing